Wire Sizing Chart
| Wire Sizing Chart 12V DC* | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Distance in Feet | |||||||||||
| 2' | 4' | 6' | 8' | 10' | 12' | 14' | 16' | 20' | 24' | ||
| System Amperage | 10 | 16ga | 16ga | 16ga | 14ga | 14ga | 14ga | 12ga | 12ga | 10ga | 10ga |
| 15 | 16ga | 16ga | 14ga | 14ga | 14ga | 12ga | 10ga | 10ga | 8ga | 8ga | |
| 20 | 16ga | 14ga | 14ga | 12ga | 12ga | 10ga | 10ga | 8ga | 8ga | 8ga | |
| 25 | 14ga | 14ga | 12ga | 10ga | 10ga | 10ga | 8ga | 8ga | 6ga | 6ga | |
| 30 | 14ga | 14ga | 12ga | 10ga | 10ga | 8ga | 8ga | 8ga | 6ga | 6ga | |
| 40 | 14ga | 12ga | 10ga | 8ga | 8ga | 8ga | 6ga | 6ga | 4ga | 4ga | |
| 50 | 12ga | 12ga | 10ga | 8ga | 6ga | 6ga | 6ga | 4ga | 4ga | 4ga | |
| 60 | 12ga | 10ga | 8ga | 8ga | 6ga | 6ga | 4ga | 4ga | 4ga | 2ga | |
| 70 | 12ga | 10ga | 8ga | 6ga | 6ga | 4ga | 4ga | 4ga | 2ga | 2ga | |
| 80 | 12ga | 8ga | 8ga | 6ga | 4ga | 4ga | 4ga | 2ga | 2ga | 2ga | |
| 90 | 10ga | 8ga | 6ga | 6ga | 4ga | 4ga | 2ga | 2ga | 2ga | 1ga | |
| 100 | 10ga | 8ga | 6ga | 4ga | 4ga | 4ga | 2ga | 2ga | 1ga | 1ga | |
| 120 | 10ga | 8ga | 6ga | 4ga | 4ga | 2ga | 2ga | 2ga | 1ga | 1/0 | |
| 140 | 10ga | 6ga | 4ga | 4ga | 2ga | 2ga | 2ga | 1ga | 1/0 | 2/0 | |
| 160 | 8ga | 6ga | 4ga | 2ga | 2ga | 2ga | 1ga | 1/0 | 2/0 | 2/0 | |
| 180 | 8ga | 6ga | 4ga | 2ga | 2ga | 1ga | 1/0 | 1/0 | 2/0 | 3/0 | |
| 200 | 8ga | 4ga | 4ga | 2ga | 1ga | 1ga | 1/0 | 2/0 | 3/0 | 3/0 | |
| 250 | 6ga | 4ga | 2ga | 1ga | 1/0 | 1/0 | 2/0 | 3/0 | 3/0 | 4/0 | |
| 300 | 6ga | 4ga | 2ga | 1ga | 1/0 | 2/0 | 3/0 | 3/0 | 4/0 | 2-2/0 | |
| 350 | 6ga | 2ga | 1ga | 1/0 | 2/0 | 3/0 | 3/0 | 4/0 | 2-2/0 | 2-3/0 | |
| 400 | 4ga | 2ga | 1ga | 2/0 | 3/0 | 3/0 | 4/0 | 2-2/0 | 2-3/0 | 2-3/0 | |
* For 24 volt use, divide the amperage by two.
This table was calculated for a 12V system assuming, a .36 voltage drop for starting and a .44 voltage drop for charging, a maximum operating temperature of 150F. A larger wire can be used to decrease the voltage drop or to operate at a higher temperature.